Search results for "flow [Keywords]"
showing 10 items of 469 documents
Nitrogen recovery using a membrane contactor: Modelling nitrogen and pH evolution
2020
[EN] A hollow fibre membrane contactor has been applied for nitrogen recovery from anaerobic digestion supernatant at different operating conditions obtaining nitrogen recovery efficiencies over 99 %. A mathematical model able to represent the time evolution of pH and nitrogen concentration during the recovery process is presented in this paper. The developed model accurately reproduced the results obtained in 26 experiments carried out at different pH values (from 9 to 11), temperatures (from 25 to 35 degrees C), membrane surfaces (from 1.2 to 2.4 m(2)) and feed flow rates (from 0.33 x 10(-5) to 5.83 x 10(-5) m(3)/s) predicting the variations in nitrogen recovery rates measured at the diff…
Observable Quantities for Electrodiffusion Processes in Membranes
2008
Electrically driven ion transport processes in a membrane system are analyzed in terms of observable quantities, such as the apparent volume flow, the time dependence of the electrolyte concentration in one cell compartment, and the electrical potential difference between the electrodes. The relations between the fluxes and these observable quantities are rigorously deduced from balances for constituent mass and solution volume. These relations improve the results for the transport coefficients up to 25% with respect to those obtained using simplified expressions common in the literature. Given the practical importance of ionic transport numbers and the solvent transference number in the ph…
Kinetic study of ionic liquid synthesis in a microchannel reactor
2010
Abstract A microchannel reaction system, mainly consisting of a micromixer and a tubular reactor, was used to investigate the kinetics of butylation of 1-methyl-imidazole [MIM] for the synthesis of the ionic liquid 1-butyl-3-methylimidazolium bromide ([BMIM]Br). The low variance (σθ2 = 0.019) of the residence time distribution, measured by a step stimuli–response tracer method, implies that this reaction system could be regarded as a plug flow reactor. As a fast and reliable method, the titration of bromide was established to determine the yield of [BMIM]Br. The reaction kinetics was studied by varying the molar ratio of 1-bromobutane [BrBu] to [MIM] (1.04–1.49) and temperature (75–90 °C). …
Microsurgical Management of Intracranial Aneurysms After Flow Diversion Failure
2019
Subarachnoid hemorrhage (SAH) occurring after an intracranial aneurysm rupture has an incidence of 10.5 per 100,000 person-years and accounts for about 5% of strokes. The resulting outcome depends on several factors including the severity of the initial hemorrhage, rebleeding, perioperative medical management, and the timing and technical success for aneurysm treatment. The overall mortality rates from 32%−67% with 10%–20% of patients with long-term dependence due to brain damage. It is well known that 12% of patients die before achieving medical treatment and 25% die within the first 24 hours. Again, 40%–60% mortality rate occurs within 30 days. Among the surviving patients, about one thir…
Climate change effects on the hydrological regime of small non-perennial river basins.
2015
Recent years have been witnessing an increasing interest on global climate change and, although we are only at the first stage of the projected trends, some signals of climate alteration are already visible. Climate change encompasses modifications in the characteristics of several interrelated climate variables, and unavoidably produces relevant effects on almost all the natural processes related to the hydrological cycle. This study focuses on potential impacts of climate variations on the streamflow regime of small river basins in Mediterranean, seasonally dry, regions. The paper provides a quantitative evaluation of potential modifications in the flow duration curves (FDCs) and in the p…
Annual flow duration curves assessment in ephemeral small basins
2014
Flow duration curve (FDC) represents a comprehensive signature of temporal runoff variability often used to synthesize catchment rainfall-runoff responses. A new model, the ModABa (MODel for Annual flow duration curves assessment in ephemeral small BAsins), is here introduced. It can be thought as a wide mosaic whose tesserae are frameworks, models or conceptual schemes separately developed in different studies and harmoniously interconnected with the final aim of reproducing the annual FDC in intermittent small catchments. Two separated seasons within the hydrological year are distinguished: a dry season, characterized by absence of streamflow, and a non-zero season. Streamflow is disaggre…
Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve …
2007
Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter.We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from …
A new algorithm for a robust solution of the fully dynamic Saint-Venant equations
2003
A new procedure for the numerical solution of the fully dynamic shallow water equations is presented. The procedure is a fractional step methodology where the original system is split into two sequential ones. The first system differs from the original one because of the head gradient term, that is treated as constant and equal to the value computed at the end of the previous time step. The solution of this system, called kinematic, is computed in each element using a spatial zero order approximation for both the heads and the flow rates by means of integration of single ODEs. The second system is called diffusive, contains in the momentum equations only the complementary terms and can be e…
Measurement uncertainty impact on simplified load flow analysis in MV smart grids
2018
This work is focused on the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. In more detail, the paper presents the uncertainty evaluation of a simplified load flow algorithm, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). To reduce the costs of the monitoring system, the load flow algorithm makes use of LV load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on the algorithm input quantities (load powers and slack b…
Origin and correction of the deviations in retention times at increasing flow rate with Chromolith columns.
2010
Chromoliths can be used at flow rates beyond those feasible for conventional microparticulate packed columns. Ideally, the plots of the retention time versus the inverse of delivered flow rate should exhibit y-intercept of zero. However, significant positive deviations correlating with the solute polarity were observed for several compounds chromatographed with a Chromolith column, owing to the increased system pressure. Consequently, the dead time marker exhibits a smaller deviation, making the retention factors depend on the flow rate. Chromoliths are made of a silica-based monolith encapsulated within a PEEK tube, and should suffer larger stress with pressure than stainless steel columns…